Power transformers

Step-up and step-down transformers up to 50 MVA, 132 kV, for transmission and industry.

3.15 MVA – 50 MVA · up to 132 kV

Power transformer

Data sheet

Technical data

Technical data: power transformers
Rating
Capacity3.15 MVA – 50 MVA
Voltage class11, 22, 33, 66 or 132 kV
PhasesSingle-phase or three-phase
Testing
Type testingDesigns type-tested up to 20 MVA, 33/11 kV at CPRI or ERDA
Construction
CoreGenerally CRGO
ConductorCopper or aluminium, per customer requirement
PreservationConventional conservator, free-breathing; dehumidifying breather or air-cell bladder
Cooling
Cooling classONAN/ONAF
Cooling arrangementCorrugated fins or pressed-steel radiators
Insulating liquidPCB-free mineral oil, Midel 7131, silicone oil or Nynas Nytro
Regulation
Tap changerOn-load tap changer (OLTC) with RTCC and AVR above 500 kVA, on request
Environment
Ambient, temperature rise and altitudeTo customer specification
Standards
Designed toIEC 60076, IS 2026, ANSI and BS

Final ratings, losses, impedance and dimensions are confirmed in the guaranteed technical particulars (GTP) for each order.

Overview

Power transformers step voltage up for transmission and down for sub-transmission and industrial supply. We build them as free-breathing units with a conventional conservator. A dehumidifying breather or air-cell bladder is available. Units are filled with PCB-free mineral oil, Midel 7131, silicone oil or Nynas Nytro, as the customer requires, and on-load tap changers (OLTC) with RTCC and AVR can be supplied.

Applications

  • Transmission and sub-transmission substations
  • Generation step-up
  • Utility power projects
  • Heavy industrial plants

Design and engineering features

  • CRGO core; copper or aluminium conductors
  • ONAN/ONAF cooling, with corrugated fins or pressed-steel radiators
  • Conventional conservator, free-breathing, with a dehumidifying breather or air-cell bladder
  • On-load tap changer (OLTC) with RTCC and AVR above 500 kVA, on request
  • Choice of insulating liquid: PCB-free mineral oil, Midel 7131, silicone oil or Nynas Nytro
  • Indoor or outdoor installation; altitude and ambient conditions to specification